The Tunable CW/Pulsed External Cavity Quantum Cascade Laser (ECqcL™) system is the laboratory work horse, providing both Continuous Wave (CW) and Pulsed performance. Tuning ranges of many models have been expanded. The new HFQD control architecture allows for longer pulses and higher repetition rates as well as provides more chip protection and a more versatile modulation circuit for CW operation.

And now introducing over 100cm-1 of tunability at 3.25µm (3080 cm-1) to probe hydrocarbon stretches!
  • Tunable Laser Controller (front)
  • Tunable Laser Controller (back)
  • Tunable Laser Controller

Features


  • Over 17 center wavelengths offered, including 3.25 µm
  • HFQD control architecture
  • True CW or Pulsed operation
  • Expanded tuning ranges
  • High output powers
  • Narrow linewidths
  • Fully functional controller, including TEC, remote access
  • Room-temperature operation

Benefits


  • Access to your target system
  • Better pulses, CW modulation control, & chip protection
  • Flexible control over experiment design
  • Access more molecules per laser
  • Higher sensitivity experiments
  • High resolution data
  • Ease of use and flexibility
  • No cryogenic cooling (water chiller required for CW operation)

Product Details


Introducing 3.25 µm (3080 cm-1) coverage of the hydrocarbon stretching region.

Daylight Solutions is pleased to provide the world’s first broadly tunable mid-IR lasers based on quantum cascade (QCL) and other semiconductor technology. Seventeen models with center wavelengths spanning the mid-IR spectrum from 3.25 μm to 10.4 μm provide continuous tuning of up to 120 cm-1. New expanded tuning ranges are now offered on most models. These lasers operate in both Pulsed and CW modes and are appropriate for applications requiring narrow linewidth and wavelength stability, though they do not tune mode hop-free in CW mode.

Designed by the world’s leading experts in mid-IR tunable lasers, these sources are small, robust, and utilize specially designed, patented1 miniature lenses to optimize system performance. Each system integrates thermoelectric cooling for room-temperature operation. In Pulsed operation, the lasers are passively cooled and only a water chiller is needed when operating in CW mode – no cryogenic cooling ever!

Each tunable laser operates with an intuitive, easy-to-use multifunction controller now featuring the HFQD control architecture. HFQD (High-Fidelity Quantum Cascade Drive) provides better-formed, longer pulses as well as higher repetition rates. HFQD also provides broader modulation bandwidth (DC to 1 MHz) for CW operation and better protection circuitry for the gain chip. Full control of laser operation is available from the front panel of the controller or through an RS-232, GPIB, or USB connection to your PC.

Daylight Solutions’ laser systems leverage the last 15 years of tunable laser development and manufacturing, and incorporates the company’s latest patented1 tuning and packaging technology for the mid-IR.

The availability of robust, easy-to-use tunable lasers in the 3.25 μm to 10.4 μm region of the spectrum is now a reality. These lasers enable research in the fields of molecular detection and imaging, including applications such as nano-scale imaging, microscopy, industrial process controls, detection of biomarkers in the breath, cellular imaging, and detection of chemical and biological agents.

Daylight Solutions' mid-IR laser platform based on quantum cascade lasers (QCL) opens up the mid-IR to all researchers – today. We also offer detectors, broader tuning pulsed, and CW mode hop-free performance.

Call today for pricing and availability of specific wavelengths.

1This product may be covered by one or more of U.S. Patent Nos.: 7,424,042; 7,466,734; 7,492,806; 7,535,656; 7,535,936; 7,733,925; 7,796,341; 7,826,503; 7,873,094; 8,027,094; 8,050,307.  

Specifications1


Product Specifications
Operation Pulsed or CW2
 
Model Number Nominal Center
Wavelength (µm)
Nominal Center
Wavenumber (cm-1)
Tuning Range
(cm-1)
New
Performance
TLS-41032 3.25 3,080 TBD X
TLS-41036 3.55 2,820 70 X
TLS-41038 3.8 2,630 80 X
TLS-41040 4 2,500 80 X
TLS-41042 4.2 2,380 70  
TLS-41045 4.5 2,220 120 X
TLS-41047 4.7 2,130 70  
TLS-41049 4.95 2,020 70  
TLS-41052 5.2 1,920 110 X
TLS-41058 5.8 1,720 110 X
TLS-41060 6.05 1,650 110 X
TLS-41062 6.2 1,610 110 X
TLS-41074 7.4 1,350 100 X
TLS-41078 7.8 1,280 80 X
TLS-41090 8.9 1,120 80 X
TLS-41096 9.5 1,050 60  
TLS-41105 10.4 960 60  
CW Performance
Power Depends on wavelength, typically > 100 mW
Linewidth ≤100 MHz
Wavelength Drift
≤0.05 cm-1/8 hr
Current Modulation
Bandwidth DC-1 MHz
Amplitude Depth
>50%
Frequency Depth
~0.05 cm-1
Pulsed Performance
Linewidth ≤1 cm-1
Peak Power
Depends on wavelength, typically > 100 mW
Average Power
Depends on wavelength, typically > 5 mW
Power Variation
<2% rms
Pulsewidths
40-500 ns (20 ns increments)
Repetition Rate
0.1-100 kHz (100 Hz increments)
Max Duty Cycle
5%
Overall Performance
Tuning Speed ≥100 cm-1/s
Wavelength Accuracy ±1.5 cm-1 (Uni-directional)
Display Repeatability ≤0.02 cm-1
Beam Divergence <5 mrad
Beam Pointing Stability <1 mrad over 100 cm-1 tuning
Polarization Linear, Vertical , 100:1
Beam Spatial Mode TEM00
Beam M2 ≤1.3
Spot Size <2.5 mm (1/e point)
Control Specifications
Control Interface TLC-1002
HFQD-enabled Yes
Pulse Triggering Internal or external trigger, external pulse input
Scan Triggering External wavelength step, scan start
External Control Interfaces USB 2.0, GPIB, RS-232
Operating Specifications
Operating Temperature Range 15-35 °C
Cooling (Pulsed) Passive Air
Cooling (CW) Chilled water
Power Requirements 100-240 VAC, 50-60 Hz, single phase
Mechanical Specifications
Head Dimensions 5.50 x 3.45 x 3.31”
Controller Dimensions 10.51 x 8.50 x 4.00”

1 All specifications subject to change without notice
2 TLS-41036 operates only in pulsed mode

Industries & Applications


Scientific
  • Nano-scale imaging & IR microscopy
  • Photoacoustic spectroscopy (PAS)
  • Hyperspectral imaging
  • Time-Resolved Infrared Spectroscopy

Defense
  • Explosives detection
  • Chemical warfare agent detection
  • Infrared countermeasures (IRCM)
  • Infrared scene projection
  • Thermal laser pointing
  • Illumination
  • Photoacoustic spectroscopy
  • Standoff detection research
  • Hyperspectral imaging
  • Remote sensing
Medical
  • Biomedical imaging
  • Glucose monitoring

Environmental
  • Toxic industrial chemicals detection
  • Hydrocarbon detection

Industrial
  • Process control
  • Hydrocarbon detection
  • Fence line monitoring
  • Toxic industrial chemicals detection
  • Gas leak detection